Files
LAB_LINGKUNGAN/noise_report_template.html
2025-04-24 10:25:31 +07:00

552 lines
21 KiB
HTML
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
<!DOCTYPE html>
<html lang="en">
<head>
<meta charset="UTF-8">
<meta name="viewport" content="width=device-width, initial-scale=1.0">
<title>Environmental Noise Measurement Report</title>
<style>
body {
font-family: Arial, sans-serif;
margin: 0;
padding: 0;
color: #333;
font-size: 12px;
}
.container {
width: 210mm;
margin: 0 auto;
padding: 10mm;
box-sizing: border-box;
}
.header {
border-bottom: 2px solid #333;
padding-bottom: 10px;
margin-bottom: 20px;
}
.logo {
float: left;
max-height: 80px;
}
.lab-info {
float: right;
text-align: right;
}
.title {
text-align: center;
margin: 20px 0;
clear: both;
}
.title h1 {
margin: 0;
font-size: 18px;
font-weight: bold;
}
.title h2 {
margin: 5px 0;
font-size: 16px;
font-weight: normal;
}
.title h3 {
margin: 5px 0;
font-size: 14px;
font-weight: normal;
}
.clearfix::after {
content: "";
clear: both;
display: table;
}
.section {
margin-bottom: 15px;
}
.section-title {
font-weight: bold;
margin-bottom: 5px;
font-size: 13px;
background-color: #f0f0f0;
padding: 5px;
border-left: 3px solid #333;
}
table {
width: 100%;
border-collapse: collapse;
margin-bottom: 15px;
}
table, th, td {
border: 1px solid #999;
}
th {
background-color: #f0f0f0;
padding: 8px 5px;
text-align: center;
font-weight: bold;
}
td {
padding: 8px 5px;
text-align: left;
}
.text-center {
text-align: center;
}
.text-right {
text-align: right;
}
.footer {
margin-top: 30px;
border-top: 1px solid #999;
padding-top: 10px;
}
.signature {
float: right;
width: 33%;
text-align: center;
margin-top: 20px;
}
.signature-line {
border-top: 1px solid #333;
margin-top: 50px;
margin-left: auto;
margin-right: auto;
width: 80%;
}
.compliance {
padding: 3px;
border-radius: 3px;
font-weight: bold;
}
.comply {
background-color: #dff0d8;
color: #3c763d;
}
.not-comply {
background-color: #f2dede;
color: #a94442;
}
.watermark {
position: absolute;
top: 50%;
left: 25%;
transform: rotate(-45deg);
transform-origin: 50% 50%;
opacity: 0.1;
font-size: 100px;
z-index: -1;
color: #000;
white-space: nowrap;
}
.explanation-box {
background-color: #f9f9f9;
border: 1px solid #ddd;
padding: 10px;
margin: 10px 0;
font-style: italic;
}
.standard-table {
margin-top: 10px;
width: 100%;
}
.chart-container {
width: 100%;
height: 300px;
margin: 20px 0;
border: 1px solid #ddd;
padding: 10px;
box-sizing: border-box;
background-color: #f9f9f9;
text-align: center;
}
.chart-placeholder {
font-style: italic;
color: #777;
}
@page {
size: A4;
margin: 0;
}
@media print {
.container {
width: 210mm;
height: 297mm;
padding: 10mm;
box-sizing: border-box;
}
}
</style>
</head>
<body>
<div class="container">
<div class="watermark">LABORATORY REPORT</div>
<div class="header clearfix">
<img src="lab_logo.png" alt="Laboratory Logo" class="logo">
<div class="lab-info">
<h2>ENVIRONMENTAL TESTING LABORATORY</h2>
<p>Jl. Laboratorium Lingkungan No. 123, Jakarta</p>
<p>Phone: (021) 555-1234, Email: info@env-lab.co.id</p>
<p>ACCREDITED KAN: LP-001-IDN</p>
</div>
</div>
<div class="title">
<h1>ENVIRONMENTAL NOISE MEASUREMENT REPORT</h1>
<h2>REPORT NUMBER: LHU/BISING/06/2024/003</h2>
<h3>Based on PMK RI No.2 Tahun 2023</h3>
</div>
<div class="section">
<div class="section-title">1. CLIENT INFORMATION</div>
<table>
<tr>
<td width="30%">Client Name</td>
<td width="70%">PT. Industri Manufaktur Terpadu</td>
</tr>
<tr>
<td>Address</td>
<td>Jl. Kawasan Industri Blok C5, Karawang, Jawa Barat</td>
</tr>
<tr>
<td>Contact Person</td>
<td>Ir. Budi Pratama (Environmental Manager)</td>
</tr>
<tr>
<td>Request Number</td>
<td>REQ/2024/06/005</td>
</tr>
</table>
</div>
<div class="section">
<div class="section-title">2. MEASUREMENT INFORMATION</div>
<table>
<tr>
<td width="30%">Measurement Date</td>
<td width="70%">June 10, 2024</td>
</tr>
<tr>
<td>Measurement Time</td>
<td>08:00 - 17:00 WIB</td>
</tr>
<tr>
<td>Measurement Officers</td>
<td>Agus Setiawan (Sampling Officer), Dina Wijaya (Technical Analyst)</td>
</tr>
<tr>
<td>Weather Condition</td>
<td>Sunny, 30°C, Humidity 65%, Wind speed 1.5 m/s</td>
</tr>
</table>
</div>
<div class="section">
<div class="section-title">3. NOISE QUALITY STANDARDS</div>
<div class="explanation-box">
<p>According to PMK RI No.2 Tahun 2023, noise level standards are as follows:</p>
<table class="standard-table">
<tr>
<th width="40%">Area</th>
<th width="30%">Noise Level Standard</th>
<th width="30%">Time Unit</th>
</tr>
<tr>
<td>Residential Areas</td>
<td class="text-center">55 dB(A)</td>
<td class="text-center">Leq 24 hours</td>
</tr>
<tr>
<td>Commercial and Office Areas</td>
<td class="text-center">70 dB(A)</td>
<td class="text-center">Leq 24 hours</td>
</tr>
<tr>
<td>Industrial Areas</td>
<td class="text-center">70 dB(A)</td>
<td class="text-center">Leq 24 hours</td>
</tr>
<tr>
<td>Schools and Educational Institutions</td>
<td class="text-center">55 dB(A)</td>
<td class="text-center">Leq during school hours</td>
</tr>
<tr>
<td>Hospitals and Health Facilities</td>
<td class="text-center">55 dB(A)</td>
<td class="text-center">Leq 24 hours</td>
</tr>
<tr>
<td>Places of Worship</td>
<td class="text-center">55 dB(A)</td>
<td class="text-center">Leq during worship times</td>
</tr>
</table>
<p><strong>Note:</strong> Leq = Equivalent Continuous Sound Level</p>
</div>
</div>
<div class="section">
<div class="section-title">4. MEASUREMENT RESULTS</div>
<table>
<thead>
<tr>
<th rowspan="2">No.</th>
<th rowspan="2">Sampling Location</th>
<th rowspan="2">Area Description</th>
<th rowspan="2">Area Type</th>
<th colspan="3">Noise Level dB(A)</th>
<th rowspan="2">Leq 24 hour<br>dB(A)</th>
<th rowspan="2">Standard<br>dB(A)</th>
<th rowspan="2">Compliance Status</th>
</tr>
<tr>
<th>Daytime<br>(L<sub>d</sub>)</th>
<th>Evening<br>(L<sub>e</sub>)</th>
<th>Night<br>(L<sub>n</sub>)</th>
</tr>
</thead>
<tbody>
<tr>
<td class="text-center">1</td>
<td>NL-1</td>
<td>Main Factory Entrance</td>
<td>Industrial</td>
<td class="text-center">67.8</td>
<td class="text-center">65.2</td>
<td class="text-center">62.1</td>
<td class="text-center">66.3</td>
<td class="text-center">70.0</td>
<td class="text-center"><span class="compliance comply">COMPLY</span></td>
</tr>
<tr>
<td class="text-center">2</td>
<td>NL-2</td>
<td>Production Building</td>
<td>Industrial</td>
<td class="text-center">73.4</td>
<td class="text-center">72.1</td>
<td class="text-center">68.5</td>
<td class="text-center">72.2</td>
<td class="text-center">70.0</td>
<td class="text-center"><span class="compliance not-comply">NOT COMPLY</span></td>
</tr>
<tr>
<td class="text-center">3</td>
<td>NL-3</td>
<td>Office Building</td>
<td>Commercial</td>
<td class="text-center">64.5</td>
<td class="text-center">62.3</td>
<td class="text-center">58.7</td>
<td class="text-center">63.2</td>
<td class="text-center">70.0</td>
<td class="text-center"><span class="compliance comply">COMPLY</span></td>
</tr>
<tr>
<td class="text-center">4</td>
<td>NL-4</td>
<td>Facility Boundary (East)</td>
<td>Industrial</td>
<td class="text-center">68.9</td>
<td class="text-center">67.2</td>
<td class="text-center">65.6</td>
<td class="text-center">67.8</td>
<td class="text-center">70.0</td>
<td class="text-center"><span class="compliance comply">COMPLY</span></td>
</tr>
<tr>
<td class="text-center">5</td>
<td>NL-5</td>
<td>Power Generator Area</td>
<td>Industrial</td>
<td class="text-center">78.6</td>
<td class="text-center">77.5</td>
<td class="text-center">76.3</td>
<td class="text-center">77.9</td>
<td class="text-center">70.0</td>
<td class="text-center"><span class="compliance not-comply">NOT COMPLY</span></td>
</tr>
<tr>
<td class="text-center">6</td>
<td>NL-6</td>
<td>Nearest Residential Area</td>
<td>Residential</td>
<td class="text-center">57.3</td>
<td class="text-center">55.6</td>
<td class="text-center">52.1</td>
<td class="text-center">55.9</td>
<td class="text-center">55.0</td>
<td class="text-center"><span class="compliance not-comply">NOT COMPLY</span></td>
</tr>
</tbody>
</table>
<p><strong>Notes:</strong></p>
<ul>
<li>Daytime (L<sub>d</sub>): 06:00 - 18:00</li>
<li>Evening (L<sub>e</sub>): 18:00 - 22:00</li>
<li>Night (L<sub>n</sub>): 22:00 - 06:00</li>
<li>Leq 24 hour calculation: Leq = 10 × log [1/24 × (12 × 10<sup>Ld/10</sup> + 4 × 10<sup>Le/10</sup> + 8 × 10<sup>Ln/10</sup>)]</li>
</ul>
<div class="chart-container">
<p class="chart-placeholder">[Noise Level Distribution Chart - This would display a bar graph comparing measured noise levels against standards for each location]</p>
</div>
</div>
<div class="section">
<div class="section-title">5. MEASUREMENT METHOD</div>
<table>
<tr>
<th width="20%">Parameter</th>
<th width="20%">Method</th>
<th width="35%">Equipment</th>
<th width="25%">Calibration Status</th>
</tr>
<tr>
<td>Noise Level</td>
<td>SNI 7231:2009</td>
<td>Sound Level Meter Type 1 - RION NL-52 SN:12345678</td>
<td>Valid until August 15, 2024</td>
</tr>
<tr>
<td>Acoustic Calibrator</td>
<td>ANSI/ASA S1.40-2006</td>
<td>Calibrator RION NC-74 SN:87654321</td>
<td>Valid until August 15, 2024</td>
</tr>
<tr>
<td>Weather Parameters</td>
<td>In-situ measurement</td>
<td>Weather Station Kestrel 5500 SN:KW123456</td>
<td>Valid until October 10, 2024</td>
</tr>
</table>
</div>
<div class="section">
<div class="section-title">6. NOISE SOURCES AND CHARACTERISTICS</div>
<table>
<tr>
<th width="15%">Location ID</th>
<th width="35%">Major Noise Sources</th>
<th width="25%">Noise Characteristics</th>
<th width="25%">Distance to Nearest Receptor</th>
</tr>
<tr>
<td>NL-1</td>
<td>Vehicle movement, loading/unloading activities</td>
<td>Intermittent</td>
<td>200 m to office building</td>
</tr>
<tr>
<td>NL-2</td>
<td>Production machinery, metal stamping, air compressors</td>
<td>Continuous, impulsive</td>
<td>150 m to office building</td>
</tr>
<tr>
<td>NL-3</td>
<td>HVAC systems, general office activities</td>
<td>Continuous, low frequency</td>
<td>Within receptor area</td>
</tr>
<tr>
<td>NL-4</td>
<td>General facility operations, traffic on adjacent road</td>
<td>Intermittent</td>
<td>100 m to residential area</td>
</tr>
<tr>
<td>NL-5</td>
<td>Power generators, cooling systems</td>
<td>Continuous, tonal</td>
<td>120 m to office building</td>
</tr>
<tr>
<td>NL-6</td>
<td>Industrial facility noise, traffic noise</td>
<td>Intermittent, background</td>
<td>Within receptor area</td>
</tr>
</table>
</div>
<div class="section">
<div class="section-title">7. NOTES AND RECOMMENDATIONS</div>
<p>Based on the measurement results, the following findings and recommendations are provided:</p>
<ol>
<li>Three measurement locations exceed the noise threshold limits according to PMK RI No.2 Tahun 2023.</li>
<li>For the Production Building (NL-2) with noise level of 72.2 dB(A) (exceeding the 70.0 dB(A) standard), it is recommended to:
<ul>
<li>Install acoustic barriers or enclosures around high-noise machinery</li>
<li>Implement regular maintenance program to reduce noise from machinery</li>
<li>Provide hearing protection for workers in this area</li>
<li>Consider rescheduling noisy operations to reduce night time noise levels</li>
</ul>
</li>
<li>For the Power Generator Area (NL-5) with noise level of 77.9 dB(A) (significantly exceeding the 70.0 dB(A) standard), it is recommended to:
<ul>
<li>Install acoustic enclosures around generators</li>
<li>Add sound-absorbing materials to walls and ceilings in the generator room</li>
<li>Install silencers on air intakes and exhausts</li>
<li>Consider relocating generators further from office areas and property boundaries</li>
</ul>
</li>
<li>For the Nearest Residential Area (NL-6) with noise level of 55.9 dB(A) (slightly exceeding the 55.0 dB(A) residential standard), it is recommended to:
<ul>
<li>Construct a noise barrier or vegetative buffer along property boundary facing residential areas</li>
<li>Limit night-time operations of noisy equipment</li>
<li>Develop a noise monitoring program for the residential area boundary</li>
<li>Establish a community liaison program to address noise concerns</li>
</ul>
</li>
<li>General recommendations for the facility:
<ul>
<li>Develop and implement a comprehensive noise management plan</li>
<li>Conduct regular noise training for employees</li>
<li>Establish procedures for maintenance of equipment to minimize noise</li>
<li>Conduct follow-up measurements after implementing noise control measures</li>
</ul>
</li>
</ol>
</div>
<div class="section">
<div class="section-title">8. REGULATION REFERENCES</div>
<p>This measurement report refers to:</p>
<ol>
<li>Peraturan Menteri Kesehatan Republik Indonesia Nomor 2 Tahun 2023 tentang Standar Baku Mutu Kesehatan Lingkungan dan Persyaratan Kesehatan</li>
<li>SNI 7231:2009 regarding Environmental Noise Measurement Methods</li>
<li>Keputusan Menteri Lingkungan Hidup No. 48 Tahun 1996 tentang Baku Tingkat Kebisingan</li>
</ol>
</div>
<div class="footer clearfix">
<p>Report Issue Date: June 15, 2024</p>
<p>This report is only valid for the conditions during measurement and may not be reproduced partially without written approval from the laboratory.</p>
<div class="signature">
<p>Analyst</p>
<div class="signature-line"></div>
<p>Dina Wijaya</p>
<p>Environmental Analyst</p>
</div>
<div class="signature">
<p>Verified by</p>
<div class="signature-line"></div>
<p>Hendra Wijaya</p>
<p>Testing Supervisor</p>
</div>
<div class="signature">
<p>Approved by</p>
<div class="signature-line"></div>
<p>Farida Nurhasanah</p>
<p>Laboratory Manager</p>
</div>
</div>
<div style="text-align: center; margin-top: 50px; font-size: 10px;">
<p>*END OF REPORT*</p>
<p>Page 1 of 1</p>
</div>
</div>
</body>
</html>