LABORATORY REPORT

ENVIRONMENTAL TESTING LABORATORY

Jl. Laboratorium Lingkungan No. 123, Jakarta

Phone: (021) 555-1234, Email: info@env-lab.co.id

ACCREDITED KAN: LP-001-IDN

TOTAL PARTICULATE MATTER (TPM) MEASUREMENT REPORT

REPORT NUMBER: LHU/PART/06/2024/005

Based on PMK RI No.2 Tahun 2023

1. CLIENT INFORMATION
Client Name PT. Industri Manufaktur Terpadu
Address Jl. Kawasan Industri Blok C5, Karawang, Jawa Barat
Contact Person Ir. Budi Pratama (Environmental Manager)
Request Number REQ/2024/06/008
2. MEASUREMENT INFORMATION
Measurement Date June 15, 2024
Measurement Time 08:30 - 16:30 WIB
Measurement Officers Rudi Hartono (Sampling Officer), Siti Fauziah (Technical Analyst)
Weather Condition Sunny, 31°C, Humidity 68%, Wind speed 1.2 m/s
3. PARTICULATE MATTER QUALITY STANDARDS

According to PMK RI No.2 Tahun 2023, total particulate matter (TPM) standards are as follows:

Area Type TPM Standard Averaging Time
Industrial Areas 230 μg/Nm³ 24 hours
Residential Areas 90 μg/Nm³ 24 hours
Office and Commercial Areas 90 μg/Nm³ 24 hours
Parks and Green Areas 90 μg/Nm³ 24 hours
Sensitive Areas (Hospitals, Schools) 90 μg/Nm³ 24 hours

Note: μg/Nm³ = micrograms per normal cubic meter at 25°C and 760 mmHg

4. MEASUREMENT RESULTS
No. Sampling Location Area Type Sampling Time
(hours)
Parameters Standard
(μg/Nm³)
Compliance Status
TSP/TPM
(μg/Nm³)
PM10
(μg/Nm³)
1 TPM-1 Main Factory Entrance 8 215.4 112.7 230 COMPLY
2 TPM-2 Production Area (Crusher Unit) 8 287.6 156.3 230 NOT COMPLY
3 TPM-3 Office Building 8 83.1 45.6 90 COMPLY
4 TPM-4 Eastern Facility Boundary 8 176.8 89.3 230 COMPLY
5 TPM-5 Material Storage Area 8 268.2 142.5 230 NOT COMPLY
6 TPM-6 Nearest Residential Area 8 98.5 52.4 90 NOT COMPLY

Notes:

[Particulate Concentration Chart - This would display a bar graph comparing measured particulate levels against standards for each location]

5. MEASUREMENT METHOD
Parameter Method Equipment Calibration Status
Total Particulate Matter (TPM) SNI 19-7119.3-2005 High Volume Air Sampler (HVAS) Tisch TE-5000, SN: HV12345 Valid until October 5, 2024
PM10 SNI 19-7119.15-2016 PM10 Hi-Vol Sampler Tisch TE-6070, SN: PM10-7890 Valid until October 10, 2024
Weather Parameters Direct measurement Weather Station Davis Vantage Pro2, SN: WS78901 Valid until September 15, 2024
6. PARTICULATE SOURCES AND METEOROLOGICAL CONDITIONS
Location ID Major Particulate Sources Wind Direction Additional Observations
TPM-1 Vehicle traffic, material transport activities Northwest (NW) Traffic intensity: medium
TPM-2 Crushing activities, material handling, conveyor transfer points North (N) Visible dust emissions during crusher operation
TPM-3 Limited sources, mainly from HVAC system East (E) Indoor air quality; minimal outdoor influence
TPM-4 General facility operations, stockpiles, road dust Southeast (SE) Unpaved areas contributing to dust
TPM-5 Raw material stockpiles, loading/unloading operations Southwest (SW) Wind-blown dust from uncovered material piles
TPM-6 Industrial facility emissions, community activities West (W) Residential area ~500m from facility boundary
7. NOTES AND RECOMMENDATIONS

Based on the measurement results, the following findings and recommendations are provided:

  1. Three measurement locations exceed the particulate threshold limits according to PMK RI No.2 Tahun 2023.
  2. For the Production Area (Crusher Unit) with TPM level of 287.6 μg/Nm³ (exceeding the 230 μg/Nm³ standard), it is recommended to:
    • Install additional dust suppression systems (water sprays) at crusher loading and discharge points
    • Implement proper enclosure of crushing and screening equipment
    • Increase frequency of dust collection system maintenance
    • Consider installation of local exhaust ventilation with dust collectors
  3. For the Material Storage Area with TPM level of 268.2 μg/Nm³ (exceeding the 230 μg/Nm³ standard), it is recommended to:
    • Cover or enclose raw material stockpiles to prevent wind erosion
    • Implement regular water spraying of storage areas during dry conditions
    • Establish windbreaks around storage areas
    • Minimize drop heights during material transfer operations
  4. For the Nearest Residential Area with TPM level of 98.5 μg/Nm³ (exceeding the 90 μg/Nm³ residential standard), it is recommended to:
    • Establish a vegetation buffer zone between the facility and residential areas
    • Improve dust control measures at the facility boundaries nearest to residential areas
    • Schedule dust-generating activities to consider wind direction and speed
    • Implement a community complaint response system and regular monitoring program
  5. General recommendations for the facility:
    • Develop and implement a comprehensive dust management plan
    • Pave unpaved roads and implement regular road cleaning
    • Install wheel washing stations at facility exits
    • Train employees on dust control practices and proper equipment operation
    • Conduct follow-up measurements after implementing dust control measures
8. REGULATION REFERENCES

This measurement report refers to:

  1. Peraturan Menteri Kesehatan Republik Indonesia Nomor 2 Tahun 2023 tentang Standar Baku Mutu Kesehatan Lingkungan dan Persyaratan Kesehatan
  2. SNI 19-7119.3-2005 regarding Ambient Air - Part 3: Method for Sampling and Measurement of Total Suspended Particulate Using High Volume Air Sampler
  3. SNI 19-7119.15-2016 regarding Ambient Air Quality - Part 15: Method for Sampling and Measurement of PM10 Using High Volume Air Sampler with PM10 Inlet

*END OF REPORT*

Page 1 of 1